Search

Search

Allison Transmission 9.2

Allison DOC(TM) (Diagnostic Optimized Connection) For PC - Service Tool 2011 dealer diagnostic software for Allison Transmission.

New Features and Enhancements included in V9.2.0
The Allison DOC™ For PC – Service Tool V9.2.0 update includes the following enhancements:
 Updates the TRANSHEALTH™ Report feature logic to allow a TRANSHEALTH™ Report for all MY09
software levels
 Updates the connection logic so CEC2 transmission no longer connects when 1000/2000 or 3000/40000 Product
Families transmission type is selected
 Updates the Allison Transmission calculator to the latest version
 Updates the range labels for the Load-Based Shift Scheduling Economy Mode index
 Updates strip chart to save selected colors with a saved strip chart list file
 Updates utility to successfully playback snapshot files from foreign languages
 Updates strip chart to successfully print bookmarks and triggers
 Updates Data Monitor for MY06-08 1000/2000 product family to include PCS 1 Commanded Pressure
parameter

FEATURE LIST for Version 8.0.0 for Dec 18, 2008
===============================================================

1 ) Monitoring of 1K/2K and 3K/4K 4th Generation Controls.
2 ) Monitoring of CEC2 Electronic Control Unit (ECU) data.
3 ) Monitoring of CEC (On-highway and Off-highway) Electronic Control Unit (ECU) data.
4 ) Monitoring of World Transmission Electronic Control (WTEC) II/III Electronic
Control Unit (ECU) data.
5 ) TAC Data Collection capability for WTEC III ECUs.
6 ) Monitoring of 1000/2000/2400 Series Transmission Control Module (TCM) data.
7 ) Display of multiple transmission parameters and Diagnostic Trouble Codes.
8 ) Display of Failure Records.
9 ) A graphic display of limited data using analog and digital gauges.
10 ) Reprogramming of ECU or TCM settings.
11 ) Ability to activate/reset tests and tranmission capabilities (clutch
test, solenoid test, adaptive shifts, throttle calibration, etc.)
12 ) Recording of vehicle data bus information into snapshot sessions.
13 ) Display of vehicle data bus traffic.
14 ) E-mailing of snapshots along with optional comments.
15 ) Ability to Export snapshots to a comma-delimited file (4th Gen Controls only).
16 ) Ability to create/display/print diagnostic reports.
17 ) Access to transmission Troubleshooting Manuals, including context-sensitive links.
18 ) Integrated help with video-based training materials.
19 ) The ability to launch TCM Reflash when installed.
20 ) Automated application updates.
21 ) Access to Service Information Letters via the Allison Transmission web site.
22 ) Ability to monitor TRANSHEALTH(TM) status and to generate and display TRANSHEALTH(TM)
reports.
23 ) Display of vehicle prognostics information, when supported by a 4th Generation TCM.
24 ) Language support for English, French, Japanese, Spanish, Russian, German, Portuguese, Simplified Chinese, Traditional Chinese, and Korean.

INSTALLATION INSTRUCTIONS:
=========================
Notes:
- You must have administrative privileges to install and uninstall this program.
- On Windows Vista you must have administrative privileges to run the program and UAC
must be disabled.
- Allison DOC (TM) requires (and automatically installs) Adobe Acrobat Reader V7.0.
If you have previous versions of Adobe Reader on your PC, you should uninstall
those versions prior to running the Allison DOC (TM) installation program.

1 ) Insert installation CD into CD-ROM Drive.
2 ) If installation process does not begin momentarily, Select "Start"->"Settings"->"Control Panel"
from the "Start" menu on the task bar.
3 ) From the Control Panel select "Add/Remove Programs".
4 ) Select "Install" on the Add/Remove Programs Properties Dialog.
5 ) Select "Next".
6 ) Do NOT reboot/restart if prompted by Adobe Reader installation or Windows Media Player
installation.


NOTES:
=====
1 ) Some 'Help' sections of 'Allison DOC (TM)' require
'Adobe Reader'. Adobe Reader version 7.0 is automatically installed if needed.
2 ) NEXIQ Universal drivers version 1.0 are located on this CD in the "NEXIQ Universal Drivers" folder.
Run "setup.exe" to install the drivers.
3 ) NEXIQ USB-Link drivers version 5.4 are located on this CD in the "NEXIQ USB-Link v5.4" folder.
Run "USB-Link5.4.exe" to install the drivers. NEXIQ Universal drivers are not needed for the USB-Link.
4 ) The DLA 2.2.6 drivers are located on this CD in the "Noregon DLA 2.2.6" folder. Run "setup.exe"
to install the drivers.
5 ) The Noregon USB DLA v1.7 drivers are located on this CD in the "Noregon USB DLA v1.7.0.0" folder.
Run "Noregon_USB_DLA_Driver_1.7.0.0.exe" to install the drivers.
6 ) The Noregon RP1210A API Version 2.5.2.0 drivers are located on this CD in the "Noregon RP1210A API"
folder. Run "setup.exe" to install the drivers.
7 ) The DPAIV drivers are located on this CD in the "DPAIV Drivers" folder. The DPAIV drivers are
automatically installed with the application.
8 ) The Noregon Softing RP1210A API is automatically installed with the application. To use a Softing
device with the application, you must install the device drivers and copy the "can*.dll"
('*' is based on the particular device being used) to the Windows folder.


HARDWARE / SOFTWARE CONFIGURATION:
=================================

Allison DOC™ For PC – Service Tool V8.0.0 has only been tested and
validated on PCs with the following configurations:
o Microsoft® Windows XP® Professional, Windows 2000® (SP4 or later)
Professional, and Windows Vista® Home Basic (or better)

Note: In order to install and run Allison DOC™ For PC – Service Tool
V8.0.0 on Windows Vista®, the user must have full administrator
privileges, and must have the User Account Control feature turned
OFF.

o 20 GB Hard Drive, (40 GB or greater recommended)
o 600 MB free hard drive space required to install the program (after
software installation, the operating system requires sufficient free
hard disk space to run the program)
o 1GHz (or greater) 32-bit (x86) or 64-bit (x64) processor
o 512MB of RAM system memory (1GB recommended)
o One available USB port—USB 1.1 (USB 2.0 recommended)
o A serial port is required if connecting legacy CEC1 controllers, or
if using the J 44652-A - SPX J1850-VPW (Class 2) translator device
o 16x CD-ROM, (48x or greater recommended)
o Full administrative privileges are required to install, use, and
update the Allison DOC™ For PC–Service Tool
o Internet connection capability (Internet Explorer® 5.0.1 or greater)
(NOTE: A broadband internet connection is recommended for receiving
updates and file downloads)
o Adobe® Acrobat Reader® is installed by default

Error messages, sudden disconnections, and poor performance are some of
the results users will experience if Allison DOC™ For PC – Service Tool
V8.0.0 is installed on PCs that do not meet one or more of the above
specifications.

Translator Device Support:
o For B&B J1708D15 - Noregon RP1210A API version V2.5.2.0 or better.
o For Noregon DLA - V2.2.6 drivers or better; V2.2 firmware.
o For Noregon USB DLA - V1.7 drivers or better; V1.11 firmware.
o For Magikey PDM - NEXIQ Universal drivers V1.0 or better.
o For NEXIQ USB-Link - NEXIQ USB-Link V5.4 or better.
o For Dearborn DPAIV - Drivers are automatically installed with the application.
o For SPX AT1J1850 - no drivers are required.



Catalogue type: Diagnostics
Regions: All regions 
Language: Russian
English
Japanese
French
Spanish
 
Operating system: WinXP, Windows 7/8/10
Disk amount: 1 DVD
 
Date: 11/2011 
Price: 40 USD

Return to catalog


Screenshots:

Click on small picture and you may see screenshot in full screen.

Allison Transmission 9.2 diagnostic software Allison DOC(TM) (Diagnostic Optimized Connection) For PC
 
Allison Transmission 9.2 diagnostic software Allison DOC(TM) (Diagnostic Optimized Connection) For PC
 
Allison Transmission 9.2 diagnostic software Allison DOC(TM) (Diagnostic Optimized Connection) For PC
 
Allison Transmission 9.2 diagnostic software Allison DOC(TM) (Diagnostic Optimized Connection) For PC
 

 

 

Return to catalog

Related products:


1Allison Transmission 13.2
Diagnostic software for Allison Transmission 13.2
Diagnostics
2Allison Troubleshooting Manual Allison MD/HD Product Lines On-Highway Transmissions WTEC III Electronic Controls
Troubleshooting Manual
Repair manuals
3Allison Transmission 3000/4000 4th Generation
Allison Transmission 4TH GENERATION CONTROLS VOCATIONAL MODELS - Service Manual, Troubleshooting Manual
Repair manuals
4Allison Transmission Parts Catalog 5000 and 6000 product families
spare parts catalog
Spare parts catalog
5Allison Transmission 2017
Allison DOC, (Diagnostic Optimized Connection) For PC
Diagnostics
6Allison Transmission Parts Catalog 1000 and 2000 product families
spare parts catalog
Spare parts catalog
7Allison Transmission 9.2
diagnostic software Allison DOC(TM) (Diagnostic Optimized Connection) For PC
Diagnostics
8Allison Transmission MT600, HT700, CLT700
service manual
Repair manuals
9Allison Transmission 9.2
Allison DOC, (Diagnostic Optimized Connection) For PC 
Diagnostics
10Allison Transmission Parts Catalog 3000 product families
spare parts catalog
Spare parts catalog